Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/11238
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPradhan, Girija Sankaren_US
dc.contributor.authorSahoo, Raghunathen_US
dc.contributor.authorScaria, Ronalden_US
dc.date.accessioned2023-01-23T14:08:23Z-
dc.date.available2023-01-23T14:08:23Z-
dc.date.issued2022-
dc.identifier.citationChandra, A., Ahmad, S., Chakraborty, M., Dugad, S. R., Goswami, U. D., Gupta, S. K., . . . Zuberi, M. (2022). An extensive study for correcting the nonlinear particle density measured by GRAPES-3 scintillator detectors. Paper presented at the Proceedings of Science, , 395 Retrieved from www.scopus.comen_US
dc.identifier.issn1824-8039-
dc.identifier.otherEID(2-s2.0-85143775377)-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/11238-
dc.description.abstractThe GRAPES-3 extensive air shower (EAS) array located at Ooty is equipped with 400 plastic scintillator detectors spread over an area of 25,000 m2 and a muon telescope of area 560 m2 built with 3,712 proportional counters. One of its principal objectives is to measure the primary cosmic ray energy spectrum in the TeV-PeV energy region. The response of the photo-multiplier tubes (PMTs) used in the plastic scintillator detectors becomes nonlinear at densities &gten_US
dc.description.abstract50 particles-m−2 in large EAS. We describe a technique to correct for the nonlinearity of these PMTs, thereby extending the dynamic range of the detectors for observed particle densities up to ∼5000 particles-m−2. The details of the technique will be presented. © Copyright owned by the author(s) under the terms of the Creative Commons.en_US
dc.language.isoenen_US
dc.publisherSissa Medialab Srlen_US
dc.sourceProceedings of Scienceen_US
dc.subjectCosmologyen_US
dc.subjectPhotomultipliersen_US
dc.subjectPositron emission tomographyen_US
dc.subjectScintillation countersen_US
dc.subjectCosmic ray energy spectrumen_US
dc.subjectDynamic rangeen_US
dc.subjectEnergy regionsen_US
dc.subjectExtensive air showersen_US
dc.subjectMuon telescopeen_US
dc.subjectParticle densitiesen_US
dc.subjectPhoto multiplier tubeen_US
dc.subjectPlastic scintillator detectoren_US
dc.subjectScintillator detectoren_US
dc.subjectShower arrayen_US
dc.subjectCosmic raysen_US
dc.titleAn extensive study for correcting the nonlinear particle density measured by GRAPES-3 scintillator detectorsen_US
dc.typeConference Paperen_US
Appears in Collections:Department of Physics

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: