Title: MoS2/S@g-CN Composite Electrode for L-Tryptophan Sensing
Authors: Chaudhary, Archana
Keywords: cyclic voltammetry;differential pulse voltammetry (DPV);L-tryptophan;MoS2/S@g-C3N4;sensors
Issue Date: 2023
Publisher: Multidisciplinary Digital Publishing Institute (MDPI)
Citation: Joshi, J., Sharma, P., & Sahu, S. K. (2023). EFFECT OF PROTRUSIONS ARRANGEMENTS ON THE THERMAL PERFORMANCE OF JET IMPINGEMENT COOLING FOR A CURVED SURFACE. International Conference on Nuclear Engineering, Proceedings, ICONE. Scopus. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85178517743&partnerID=40&md5=101573025d415808cc54070eccfbad72
Abstract: L-tryptophan (L-TRP) is an essential amino acid responsible for the establishment and maintenance of a positive nitrogen equilibrium in the nutrition of human beings. Therefore, it is vital to quantify the amount of L-tryptophan in our body. Herein, we report the MoS2/S@g-CN-modified glassy carbon electrode for the electrochemical detection of L-tryptophan (L-TRP). The MoS2/S@g-CN composite was successfully synthesized using an efficient and cost-effective hydrothermal method. The physical and chemical properties of the synthesized composite were analyzed using powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and energy-dispersive X-ray analysis (EDX). The crystallite size of the composite was calculated as 39.4 nm, with porous balls of MoS2 decorated over the S@g-CN surface. The XPS spectrum confirmed the presence of Mo, S, O, C, and N elements in the sample. The synthesized nanocomposite was further used to modify the glassy carbon (GC) electrode (MoS2/S@g-CN/GC). This MoS2/S@g-CN/GC was used for the electrochemical detection of L-TRP using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. For the purpose of comparison, the effects of the scanning rate and the concentration of L-TRP on the current response for the bare GC, S@g-CN/GC, MoS2/GC, and MoS2/S@g-CN/GC were studied in detail. The MoS2/S@g-CN-modified GC electrode exhibited a rational limit of detection (LoD) of 0.03 µM and a sensitivity of 1.74 µA/ µMcm2, with excellent stability, efficient repeatability, and high selectivity for L-TRP detection. © 2023 by the authors.
URI: https://doi.org/10.3390/bios13110967
https://dspace.iiti.ac.in/handle/123456789/12806
ISSN: 2079-6374
Type of Material: Journal Article
Appears in Collections:Department of Chemistry