Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/13092
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChaudhary, Sandeepen_US
dc.date.accessioned2024-01-17T10:37:41Z-
dc.date.available2024-01-17T10:37:41Z-
dc.date.issued2024-
dc.identifier.citationSrimuang, K., Imjai, T., Kefyalew, F., Raman, S. N., Garcia, R., & Chaudhary, S. (2024). Thermal and acoustic performance of masonry walls with phase change materials: A comparison of scaled-down houses in tropical climates. Journal of Building Engineering. Scopus. https://doi.org/10.1016/j.jobe.2023.108315en_US
dc.identifier.issn2352-7102-
dc.identifier.otherEID(2-s2.0-85180542281)-
dc.identifier.urihttps://doi.org/10.1016/j.jobe.2023.108315-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/13092-
dc.description.abstractThis article examines experimentally and numerically the effectiveness of Phase Change Materials (PCMs) and a new type of hybrid sandwich insulated panel (SIP) at improving the thermal comfort of four case study houses built in Thailand. In Phase 1 of the experimental programme, three scaled-down house units were built with either a) traditional brick walls plastered with a cement-based mortar, b) brick walls plastered with a cement-based mortar mixed with a 15% of PCMs, or c) a new SIP panel termed UWall. The results are discussed in terms of temperature, relative humidity (RH), energy consumption and acoustic performance. It was found that the PCM plastering and UWall effectively reduced the temperatures in the unit between 1 °C and up to 5 °C compared to the counterpart unit with brick walls plastered with cement-based mortar. In Phase 2 of the tests, a 10 × 7 m full-scale house was built with one room built with brick walls plastered with the cement-based mortar-PCM mixture, and one room built with the new UWall. Temperature, RH and indoor air movement were recorded for 48 h. Results from a bioclimatic chart indicates that both temperature and RH in the rooms remained within the comfort zone at all times if air movement is considered. The three units and full-scale house were then modelled in ANSYS® software to carry out a heat transfer analysis. The modelling approach was successful at predicting the maximum temperatures in the tested case study houses (accuracy <7%). For the case study houses and climate conditions considered in this study, the mortar-PCM plastering proved a practical retrofitting solution to improve the thermal performance, RH, energy efficiency and acoustic resistance of existing brick walls. Similar solutions could be adopted to improve the thermal comfort in masonry walls of existing buildings. This article contributes towards developing more effective solutions to improve the thermal comfort in existing houses and buildings located in tropical regions, which in turn can help reduce energy consumption. © 2023 Elsevier Ltden_US
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.sourceJournal of Building Engineeringen_US
dc.subjectAcoustic performanceen_US
dc.subjectComfort zoneen_US
dc.subjectHeat transferen_US
dc.subjectHybrid composite wallen_US
dc.subjectPhase change materialsen_US
dc.subjectThermal performanceen_US
dc.titleThermal and acoustic performance of masonry walls with phase change materials: A comparison of scaled-down houses in tropical climatesen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Civil Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: