Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/14219
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGhosh, Saptarshien_US
dc.date.accessioned2024-08-14T10:23:44Z-
dc.date.available2024-08-14T10:23:44Z-
dc.date.issued2024-
dc.identifier.citationDewangan, L., Mishra, N. K., & Ghosh, S. (2024). Angularly Stable High-Q Factor Metamaterial Absorber for Bio-Medical Sensing Applications. IEEE Sensors Letters. https://doi.org/10.1109/LSENS.2024.3414337en_US
dc.identifier.issn2475-1472-
dc.identifier.otherEID(2-s2.0-85196071980)-
dc.identifier.urihttps://doi.org/10.1109/LSENS.2024.3414337-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/14219-
dc.description.abstractIn this paper, a thin, high Q-factor, angularly stable, and polarization-insensitive metamaterial absorber (MMA) for sensing applications is presented. The absorber operates at the C-band, having near-unity absorptivity. The symmetric design is polarization-insensitive under normal incidence. In addition, the novel design shows more than 90&#x0025en_US
dc.description.abstractabsorptivity up to 80&#x00B0en_US
dc.description.abstractincident angle for both transverse electric (TE) and transverse magnetic (TM) polarized waves under oblique incidence. The absorption mechanism is described with the help of surface current distribution, induced electric field, and parametric analysis. To verify the resonance characteristic of the structure, an equivalent circuit analysis has been presented. A precise shift in the absorption frequency is observed in response to alteration in the permittivity value of a material placed above the geometryen_US
dc.description.abstracthence, the proposed structure can be used as a refractive index sensor. Multiple characteristics, such as thin profile, high angular stability, polarization insensitiveness, and high Q factor make the proposed MMA highly desirable in refractive index sensing for biomedical applications IEEEen_US
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceIEEE Sensors Lettersen_US
dc.subjectAbsorptionen_US
dc.subjectBiosensorsen_US
dc.subjectGeometryen_US
dc.subjectHigh-Q factoren_US
dc.subjectIncident angle independenten_US
dc.subjectMetamaterial absorberen_US
dc.subjectPolarization insensitiveen_US
dc.subjectQ-factoren_US
dc.subjectRefractive indexen_US
dc.subjectRefractive index Sensoren_US
dc.subjectSensor applicationsen_US
dc.subjectSensor phenomena and characterizationen_US
dc.subjectSensorsen_US
dc.titleAngularly Stable High-Q Factor Metamaterial Absorber for Bio-Medical Sensing Applicationsen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Electrical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: