Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/15952
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPhukan, Nabasmitaen_US
dc.contributor.authorPachori, Ram Bilasen_US
dc.date.accessioned2025-04-22T17:45:35Z-
dc.date.available2025-04-22T17:45:35Z-
dc.date.issued2025-
dc.identifier.citationPhukan, N., Manikandan, M. S., & Pachori, R. B. (2025). Resource-Efficient CNN Based Atrial Fibrillation Detection Using P-wave and RR Interval Features for Edge-AI Cardiac Health Monitoring Devices. IEEE Transactions on Artificial Intelligence. https://doi.org/10.1109/TAI.2025.3556995en_US
dc.identifier.issn2691-4581-
dc.identifier.otherEID(2-s2.0-105002602957)-
dc.identifier.urihttps://doi.org/10.1109/TAI.2025.3556995-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/15952-
dc.description.abstractAtrial fibrillation (AF) is a cardiac arrhythmia which leads to ischemic stroke. This paper presents a real-time AF detection method with reduction in energy consumption and false alarms for wearable devices. The method is designed with a 1D-convolutional neural network (CNN), RR interval, and P-wave features. The training dataset contains the Fourier magnitude spectrum and RR intervals of 10-second electrocardiogram (ECG) segments from five benchmark ECG databases (1-lead, 2-lead, and 12-lead). The 1D-CNN-based AF detection methods are tested with two untrained datasets (2-lead and 12-lead) and 20% of the trained dataset. The optimal trade-off between performance and computational complexity is achieved using 5-layer CNN model (activation function: exponential linear unit and kernel size: 4×1) with a model size of 4.33MB and processing time of 0.100ms. The CNN-RRI-FMS based AF detection method has an overall accuracy, sensitivity, and specificity of 99.44%, 98.76%, and 99.81%, respectively. The method is validated on Raspberry-Pi. The method has an average latency and energy consumption of 3.52ms and 10.76mJ for a 10-second ECG segment on Raspberry Pi. Comparative analysis with prior studies and existing deep-learning networks signifies the superiority of the method in terms of performance, computational complexity, and energy efficiency. The experimental results emphasize its suitability for real-time implementations in cardiac health monitoring devices. © 2020 IEEE.en_US
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceIEEE Transactions on Artificial Intelligenceen_US
dc.subjectAtrial fibrillationen_US
dc.subjectConvolutional neural networken_US
dc.subjectFourier magnitude spectrumen_US
dc.subjectOn-device AIen_US
dc.subjectRR intervalen_US
dc.titleResource-Efficient CNN Based Atrial Fibrillation Detection Using P-wave and RR Interval Features for Edge-AI Cardiac Health Monitoring Devicesen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Electrical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: