Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/19188
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBailung, Yoshini.en_US
dc.contributor.authorBehera, Debadattaen_US
dc.contributor.authorGoswami, Kangkanen_US
dc.contributor.authorGupta, Ramnien_US
dc.date.accessioned2026-09-21T12:20:41Z-
dc.date.available2026-09-21T12:20:41Z-
dc.date.issued2026-
dc.identifier.citationAbualrob, Acharya, Aglieri Rinella, Aglietta, Agrawal, Ahammed, Ahmad, Ahuja, Akbar, Akindinov, Akishina, Al-Turany, Aleksandrov, Alessandro, Alfaro Molina, Ali, Alici, Alkin, Alme, … Zurlo. (2026b). Time resolution of the ALICE time-of-flight detector with the first Run 3 pp collisions at s=13.6 TeV. European Physical Journal Plus, 141(8). https://doi.org/10.1140/epjp/s13360-026-07626-4en_US
dc.identifier.issn2190-5444-
dc.identifier.otherEID(2-s2.0-105049246861)-
dc.identifier.urihttps://dx.doi.org/10.1140/epjp/s13360-026-07626-4-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/19188-
dc.description.abstractParticle identification (PID) is a fundamental aspect of the ALICE detector system, central to its heavy-ion and proton–proton physics programs. Among the different PID strategies, ALICE uses the time-of-flight (TOF) detector to identify particles at intermediate momenta (0.5<pT<4GeV/c). The ALICE TOF detector performed successfully during the first 10 years of LHC operations. During the Long Shutdown 2, many ALICE sub-detectors, including TOF, were upgraded to fully leverage the targeted 50 kHz interaction rate of Pb–Pb collisions, which required the implementation of a continuous readout scheme. The TOF detector electronics were upgraded and refurbished, while processing algorithms for data quality control, reconstruction, calibration, and analysis were rewritten. This paper presents the upgraded TOF detector operation and calibration procedures and its performance in terms of timing resolution, a key factor for particle separation in ALICE analyses. Using 2022 pp collision data at s=13.6TeV from Run 3, the time resolution of the detector was estimated with two independent methods, both yielding consistent results, better than 80 ps. Despite the excellent performance already achieved, further improvements are expected after additional detector commissioning and refined calibration procedures, thus enhancing the ALICE PID capabilities for Run 3 and beyond. © The Author(s) 2026.en_US
dc.language.isoenen_US
dc.publisherSpringer Science and Business Media Deutschland GmbHen_US
dc.sourceEuropean Physical Journal Plusen_US
dc.titleTime resolution of the ALICE time-of-flight detector with the first Run 3 pp collisions at s=13.6 TeVen_US
dc.typeJournal Articleen_US
dc.rights.licenseAll Open Access-
dc.rights.licenseGreen Open Access-
dc.rights.licenseHybrid Gold Open Access-
Appears in Collections:Department of Physics

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: