Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/3976
Title: Application of single and dual fluorophore-based pH sensors for determination of milk quality and shelf life using a fibre optic spectrophotometer
Authors: Choudhary, Sandeep
Joshi, Bhavana
Pandey, Gaurav
Joshi, Abhijeet B.
Keywords: Biosensors;Dairies;Fluorophores;pH;Ruthenium compounds;FITC-Rubpy;Fluorescein isothiocyanate;High nutrients;Percentage recovery;Quick response time;Reproducibilities;Research reports;Solution phase;pH sensors
Issue Date: 2019
Publisher: Elsevier B.V.
Citation: Choudhary, S., Joshi, B., Pandey, G., & Joshi, A. (2019). Application of single and dual fluorophore-based pH sensors for determination of milk quality and shelf life using a fibre optic spectrophotometer. Sensors and Actuators, B: Chemical, 298 doi:10.1016/j.snb.2019.126925
Abstract: Milk is a high nutrient value food substance consumed by the entire population in several forms. Spoilage and degradation of milk and its products during transportation, processing and packaging are some of the major losses by dairy industries. The change in milk pH with time is an indicating factor of milk degradation. This research reports a rapid, sensitive and facile fluorescence-based technique to study the time-based milk degradation at room temperature. Fluorescein isothiocyanate (FITC)/ FITC-dextran (FITC-dex) and Tris (2, 2′-bipyridyl) dichloro ruthenium (II) hexahydrate (Ru-bpy) were used to develop solution phase and immobilized phase pH sensors. Immobilized phase sensors constituted of alginate microspheres (5 ± 3 μm) produced using an air driven atomizer. The pH sensor works in a linear range of 3–8 pH units with a quick response time of 30 s. The percentage recovery of the system lay in the range of 89.23%–101.28% for detection of milk pH. Accurate detection was possible during entire shelf life of milk (˜24 h) and Inter-sample and inter-day reproducibility was checked over 10 days duration. The results clearly indicate that both single and dual fluorophore-based assay in solution phase and immobilized phases can predict milk pH with good accuracy. © 2019 Elsevier B.V.
URI: https://doi.org/10.1016/j.snb.2019.126925
https://dspace.iiti.ac.in/handle/123456789/3976
ISSN: 0925-4005
Type of Material: Journal Article
Appears in Collections:Department of Biosciences and Biomedical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: