Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/5723
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKatiyar, Rajaten_US
dc.contributor.authorGupta, Vipinen_US
dc.contributor.authorPachori, Ram Bilasen_US
dc.date.accessioned2022-03-17T01:00:00Z-
dc.date.accessioned2022-03-17T15:43:30Z-
dc.date.available2022-03-17T01:00:00Z-
dc.date.available2022-03-17T15:43:30Z-
dc.date.issued2019-
dc.identifier.citationKatiyar, R., Gupta, V., & Pachori, R. B. (2019). Fbse-ewt-based approach for the determination of respiratory rate from ppg signals. IEEE Sensors Letters, 3(7) doi:10.1109/LSENS.2019.2926834en_US
dc.identifier.issn2475-1472-
dc.identifier.otherEID(2-s2.0-85081984668)-
dc.identifier.urihttps://doi.org/10.1109/LSENS.2019.2926834-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/5723-
dc.description.abstractRespiratory rate (RR) is a vital parameter that shows signs of abnormal human breathing activity. There are various techniques for extracting RR. In addition to oxygen saturation (SpO2) and cardiac rate measurement, the photoplethysmography (PPG) signal can be used to obtain breathing information that prevents the additional measurement sensor from being used. An algorithm has been suggested for the extraction of respiratory data from PPG signals using Fourier-Bessel series expansion-based empirical wavelet transform (FBSE-EWT) in this article. We have taken 310 and 632 epochs of simultaneous recorded PPG and breathing signals from the MIMIC and Capnobase databases in order to investigate the efficiency of the suggested algorithm. RR extraction from PPG signals by FBSE-EWT shows that the root mean square errors (RMSEs) for both the MIMIC and Capnobase databases are 0.48549 breaths/min and 0.92545 breaths/min, respectively. These findings show that the suggested FBSE-EWT method is more accurate in estimating RR in comparison to other existing techniques. © 2017 IEEE.en_US
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceIEEE Sensors Lettersen_US
dc.subjectExtractionen_US
dc.subjectFourier seriesen_US
dc.subjectMean square erroren_US
dc.subjectPhotoplethysmographyen_US
dc.subjectSignal processingen_US
dc.subjectFourier-Bessel series expansionen_US
dc.subjectMeasurement sensoren_US
dc.subjectPhotoplethysmographic signalsen_US
dc.subjectPhotoplethysmography (PPG)en_US
dc.subjectRate measurementsen_US
dc.subjectRespiratory rateen_US
dc.subjectRoot mean square errorsen_US
dc.subjectSensor signalsen_US
dc.subjectWavelet transformsen_US
dc.titleFbse-ewt-based approach for the determination of respiratory rate from ppg signalsen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Electrical Engineering