Please use this identifier to cite or link to this item:
https://dspace.iiti.ac.in/handle/123456789/5968
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dhanotia, Jitendra | en_US |
dc.contributor.author | Bhatia, Vimal | en_US |
dc.date.accessioned | 2022-03-17T01:00:00Z | - |
dc.date.accessioned | 2022-03-17T15:45:13Z | - |
dc.date.available | 2022-03-17T01:00:00Z | - |
dc.date.available | 2022-03-17T15:45:13Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Dhanotia, J., Bhatia, V., & Prakash, S. (2017). Collimation testing using deflectometry in conjunction with windowed fourier transform analysis. Applied Optics, 56(8), 2346-2352. doi:10.1364/AO.56.002346 | en_US |
dc.identifier.issn | 1559-128X | - |
dc.identifier.other | EID(2-s2.0-85015042720) | - |
dc.identifier.uri | https://doi.org/10.1364/AO.56.002346 | - |
dc.identifier.uri | https://dspace.iiti.ac.in/handle/123456789/5968 | - |
dc.description.abstract | In this paper, we demonstrate a simple automated procedure for the detection of collimation of an optical beam by incorporating the windowed Fourier fringe analysis technique into a deflectometric setup. The experimental arrangement consists of a deflectometry-based system in which light from a laser is expanded and passed through a collimating lens. The transmitted light illuminates a coarse sinusoidal grating. The grating image is directly captured through a charge-coupled device. Typical image patterns corresponding to "in-focus," "at-focus," and "out-of-focus" positions of an optical beam are recorded. Depending on the position of the collimating lens, the grating line spacing and the resulting phase of the emerging wavefront varies. Direct phase measurement using the windowed Fourier transform method has been used to obtain the slope map of the wavefront. The slope of the phase map depicts the diverging, collimated, or converging nature of the optical beam. The positioning error of light beam collimation was approximately 1 μm. The experimental arrangement is simple, low cost, and compact. The technique is fully automatic and provides high resolution, high precision, and good sensitivity. © 2017 Optical Society of America. | en_US |
dc.language.iso | en | en_US |
dc.publisher | OSA - The Optical Society | en_US |
dc.source | Applied Optics | en_US |
dc.subject | Charge coupled devices | en_US |
dc.subject | Wavefronts | en_US |
dc.subject | Automated procedures | en_US |
dc.subject | Collimation testing | en_US |
dc.subject | Direct phase measurement | en_US |
dc.subject | Experimental arrangement | en_US |
dc.subject | Fourier fringe analysis technique | en_US |
dc.subject | Sinusoidal grating | en_US |
dc.subject | Transmitted light | en_US |
dc.subject | Windowed Fourier transforms | en_US |
dc.subject | Fourier transforms | en_US |
dc.title | Collimation testing using deflectometry in conjunction with windowed Fourier transform analysis | en_US |
dc.type | Journal Article | en_US |
Appears in Collections: | Department of Electrical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: