Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/8149
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDutta, Surjendu Bikashen_US
dc.contributor.authorShrivastava, Rashmien_US
dc.contributor.authorKrishna, Hemanten_US
dc.contributor.authorGupta, Sharaden_US
dc.date.accessioned2022-03-17T01:00:00Z-
dc.date.accessioned2022-03-21T11:15:18Z-
dc.date.available2022-03-17T01:00:00Z-
dc.date.available2022-03-21T11:15:18Z-
dc.date.issued2019-
dc.identifier.citationDutta, S. B., Shrivastava, R., Krishna, H., Khan, K. M., Gupta, S., & Majumder, S. K. (2019). Nanotrap-enhanced raman spectroscopy: An efficient technique for trace detection of bioanalytes. Analytical Chemistry, 91(5), 3555-3560. doi:10.1021/acs.analchem.8b05371en_US
dc.identifier.issn0003-2700-
dc.identifier.otherEID(2-s2.0-85062413096)-
dc.identifier.urihttps://doi.org/10.1021/acs.analchem.8b05371-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/8149-
dc.description.abstractReliable diagnosis of disease using body fluids requires sensitive and accurate detection of disease-specific analytes present in the fluid. In recent years, there has been increasing interest in using surface-enhanced Raman spectroscopy (SERS) for this purpose. The demonstrable signal enhancement and sensitivity of SERS makes it ideally suited for detection of a trace quantity of any analyte. However, lack of reproducibility along with large spatial variability in the measured Raman intensities due to differential (and often random) distribution of surface "hot spots" limits its routine clinical use. We propose here a technique, nanotrap-enhanced Raman spectroscopy (NTERS), for overcoming these long-standing limitations and challenges of SERS. In this technique, hot spots are formed by drying up a microvolume drop of the liquid, containing the mixture of nanoparticles and analytes in the focal volume of the Raman excitation laser, and the Raman signal is detected from these spots containing the analytes localized within the nanoparticle aggregates. The performance of the technique was evaluated in detecting trace quantities of two Raman-active analytes, Rhodamine 6G (R6G) and urea. It was found that R6G and urea could be detected down to a concentration of 50 nM with signal-to-noise ratio (SNR) value of ∼75 and 4 mM with SNR value of ∼500, respectively. A comparison with SERS revealed that NTERS not only had significantly superior (around 2 orders of magnitude) signal enhancement but also had high reproducibility because of its intrinsic ability to form nanoparticle aggregates with high repetitiveness. Another advantage of NTERS is its simplicity and cost effectiveness as it does not require any specialized substrate. © 2019 American Chemical Society.en_US
dc.language.isoenen_US
dc.publisherAmerican Chemical Societyen_US
dc.sourceAnalytical Chemistryen_US
dc.subjectAggregatesen_US
dc.subjectCost effectivenessen_US
dc.subjectDiagnosisen_US
dc.subjectLaser excitationen_US
dc.subjectMetabolismen_US
dc.subjectNanoparticlesen_US
dc.subjectRaman spectroscopyen_US
dc.subjectSubstratesen_US
dc.subjectTrace analysisen_US
dc.subjectUreaen_US
dc.subjectHigh reproducibilityen_US
dc.subjectNanoparticle aggregateen_US
dc.subjectOrders of magnitudeen_US
dc.subjectRaman intensitiesen_US
dc.subjectReproducibilitiesen_US
dc.subjectSignal enhancementen_US
dc.subjectSpatial variabilityen_US
dc.subjectSurface enhanced Raman spectroscopyen_US
dc.subjectSignal to noise ratioen_US
dc.titleNanotrap-Enhanced Raman Spectroscopy: An Efficient Technique for Trace Detection of Bioanalytesen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Physics

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: