Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/8184
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRoy, Ankhien_US
dc.date.accessioned2022-03-17T01:00:00Z-
dc.date.accessioned2022-03-21T11:15:27Z-
dc.date.available2022-03-17T01:00:00Z-
dc.date.available2022-03-21T11:15:27Z-
dc.date.issued2019-
dc.identifier.citationSingh, B., Erni, W., Krusche, B., Steinacher, M., Walford, N., Liu, B., . . . Zmeskal, J. (2019). Technical design report for the PANDA barrel DIRC detector. Journal of Physics G: Nuclear and Particle Physics, 46(4) doi:10.1088/1361-6471/aade3den_US
dc.identifier.issn0954-3899-
dc.identifier.otherEID(2-s2.0-85067586562)-
dc.identifier.urihttps://doi.org/10.1088/1361-6471/aade3d-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/8184-
dc.description.abstractThe PANDA (anti-Proton ANnihiliation at DArmstadt) experiment will be one of the four flagship experiments at the new international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. PANDA will address fundamental questions of hadron physics and quantum chromodynamics using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c and a design luminosity of up to 2 × 1032 cm-2 s-1. Excellent particle identification (PID) is crucial to the success of the PANDA physics program. Hadronic PID in the barrel region of the target spectrometer will be performed by a fast and compact Cherenkov counter using the detection of internally reflected Cherenkov light (DIRC) technology. It is designed to cover the polar angle range from 22° to 140° and will provide at least 3 standard deviations (s.d.) π/K separation up to 3.5GeV/c, matching the expected upper limit of the final state kaon momentum distribution from simulation. This documents describes the technical design and the expected performance of the PANDA Barrel DIRC detector. The design is based on the successful BaBar DIRC with several key improvements. The performance and system cost were optimized in detailed detector simulations and validated with full system prototypes using particle beams at GSI and CERN. The final design meets or exceeds the PID goal of clean π/K separation with at least 3 s.d. over the entire phase space of charged kaons in the Barrel DIRC. © 2019 Institute of Physics Publishing. All rights reserved.en_US
dc.language.isoenen_US
dc.publisherInstitute of Physics Publishingen_US
dc.sourceJournal of Physics G: Nuclear and Particle Physicsen_US
dc.titleTechnical design report for the PANDA Barrel DIRC detectoren_US
dc.typeJournal Articleen_US
dc.rights.licenseAll Open Access, Hybrid Gold, Green-
Appears in Collections:Department of Physics

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: