Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/9131
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMobin, Shaikh M.en_US
dc.date.accessioned2022-03-17T01:00:00Z-
dc.date.accessioned2022-03-21T11:31:13Z-
dc.date.available2022-03-17T01:00:00Z-
dc.date.available2022-03-21T11:31:13Z-
dc.date.issued2017-
dc.identifier.citationSharma, V., & Mobin, S. M. (2017). Cytocompatible peroxidase mimic CuO:Graphene nanosphere composite as colorimetric dual sensor for hydrogen peroxide and cholesterol with its logic gate implementation. Sensors and Actuators, B: Chemical, 240, 338-348. doi:10.1016/j.snb.2016.08.169en_US
dc.identifier.issn0925-4005-
dc.identifier.otherEID(2-s2.0-84984892497)-
dc.identifier.urihttps://doi.org/10.1016/j.snb.2016.08.169-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/9131-
dc.description.abstractFaster and easy detection of cholesterol still remains a challenge. Thus, by introducing colorimetric sensor for detection of cholesterol may lead to the fabrication of a ready to use sensing strip. Our present work demonstrates the use of a cytocompatible CuO:Graphene nanosphere (CuO:GNS) composite as a peroxidase mimic for detection of H2O2 and free cholesterol. The synthesized CuO:GNS composite was investigated systematically for structural, morphological and functional aspects. The proposed methodology involves detection of H2O2 produced during oxidation of free cholesterol in the presence of cholesterol oxidase. The nanocomposite sensor has shown excellent detection sensitivity for cholesterol and has demonstrated a linear response in the range of 0.1 mM –0.8 mM with LOD as low as 78 μM. This nanocomposite sensor also detected a very low concentration of H2O2 (0.01–0.1 mM) with LOD of 6.88 μM. An AND logic gate system based on CuO:GNS and Cholesterol input was also proposed. The CuO:GNS was found to have better cytocompatibility than standalone CuO. © 2016 Elsevier B.V.en_US
dc.language.isoenen_US
dc.publisherElsevier B.V.en_US
dc.sourceSensors and Actuators, B: Chemicalen_US
dc.subjectChemical detectionen_US
dc.subjectColoren_US
dc.subjectColorimetryen_US
dc.subjectComputer circuitsen_US
dc.subjectCopper oxidesen_US
dc.subjectGrapheneen_US
dc.subjectHydrogen peroxideen_US
dc.subjectLogic gatesen_US
dc.subjectNanocompositesen_US
dc.subjectNanospheresen_US
dc.subjectOxidationen_US
dc.subjectPeroxidesen_US
dc.subjectReconfigurable hardwareen_US
dc.subjectCholesterol oxidaseen_US
dc.subjectColorimetricen_US
dc.subjectColorimetric sensorsen_US
dc.subjectDetection sensitivityen_US
dc.subjectFunctional aspectsen_US
dc.subjectLow concentrationsen_US
dc.subjectNanocomposite sensorsen_US
dc.subjectPeroxidase mimicsen_US
dc.subjectCholesterolen_US
dc.titleCytocompatible peroxidase mimic CuO:graphene nanosphere composite as colorimetric dual sensor for hydrogen peroxide and cholesterol with its logic gate implementationen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Chemistry

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: