Title: | Amplifying Quantum Tunneling Current Sensitivity through Labeling Nucleotides Using Graphene Nanogap Electrodes |
Authors: | Mittal, Sneha;Jena, Milan Kumar;Pathak, Biswarup; |
Keywords: | Cost effectiveness; Density functional theory; DNA; DNA sequences; Electrodes; Electron tunneling; Gene encoding; Nanopores; Nucleotides; Signal to noise ratio; Current sensitivity; DNA nucleotides; DNA Sequencing; Graphene nanogap; Labeled DNA nucleotide; Labelings; Nanogap electrodes; Nanogaps; Quantum tunneling; Tunneling current; Graphene |
Issue Date: | 2022 |
Publisher: | American Chemical Society |
Citation: | Mittal, S., Jena, M. K., & Pathak, B. (2022). Amplifying quantum tunneling current sensitivity through labeling nucleotides using graphene nanogap electrodes. ACS Applied Nano Materials, 5(7), 9356-9366. doi:10.1021/acsanm.2c01667 |
Abstract: | Recent advances in cost-effective, ultra-rapid, and efficient DNA sequencing are in the saddle of the advancement of the personalization of medicines for understanding and early-stage detection of several killer diseases. Paying attention to a timely need for the development of solid-state nanodevices for rapid and controlled identification of DNA nucleotides, in this report, we theoretically explored the potential of labeling techniques in the sequencing of DNA nucleotides through solid-state graphene nanogap electrodes using the quantum tunneling current approach. Our study boasts the idea that labeling of DNA nucleotides can solve major hurdles of DNA sequencing, such as improving the signal-to-noise ratio, slowing down translocation velocity, and controlling orientational variations. Employing the first-principle density functional theory study, we identify unique interaction energy values for each labeled nucleotide having remarkable differences in the range of 0.10-0.74 eV. The zero-bias transmission spectra of the proposed setup suggest that the detection of the nucleotides is possible by applying very low gate voltages. Moreover, the labeling of nucleotides amplifies the conductance sensitivity considerably. I-V characteristics suggest that electrical recognition of each labeled nucleotide can be carried out at both lower (0.3 V) and higher (0.8 V) bias voltages with single-molecule resolution, although the maximum current sensitivity is observed at a higher bias voltage. The proposed sequencing device possesses high sensitivity and selectivity characteristics that are crucial for experimental purposes. We find that our results are rich compared to unlabeled nucleotides-based graphene nanopore/nanogap devices. Hence, the study will certainly motivate the experimentalists toward the application of a labeled DNA nucleotide system for ultra-rapid DNA sequencing by using the tunneling current approach. © 2022 American Chemical Society. |
URI: | https://doi.org/10.1021/acsanm.2c01667 https://dspace.iiti.ac.in/handle/123456789/10828 |
ISSN: | 2574-0970 |
Type of Material: | Journal Article |
Appears in Collections: | Department of Chemistry |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: