Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/13054
Title: Recombinant Organophosphorus acid anhydrolase (OPAA) enzyme-carbon quantum dot (CQDs)-immobilized thin film biosensors for the specific detection of Ethyl Paraoxon and Methyl Parathion in water resources
Authors: Vyas, Tanmay
Jaiswal, Surbhi
Choudhary, Sandeep
Kodgire, Prashant
Joshi, Abhijeet B.
Keywords: Carbon quantum dots (CQD);Fluorescence;Organophosphate acid anhydrolase (OPAA);Organophosphates (OP) pesticides;Pollution;Water
Issue Date: 2024
Publisher: Academic Press Inc.
Citation: Vyas, T., Jaiswal, S., Choudhary, S., Kodgire, P., & Joshi, A. (2024). Recombinant Organophosphorus acid anhydrolase (OPAA) enzyme-carbon quantum dot (CQDs)-immobilized thin film biosensors for the specific detection of Ethyl Paraoxon and Methyl Parathion in water resources. Environmental Research. Scopus. https://doi.org/10.1016/j.envres.2023.117855
Abstract: Organophosphates pesticide (OP) toxicity through water resources is a large concern globally among all the emerging pollutants. Detection of OPs is a challenge which needs to be addressed considering the hazardous effects on the health of human beings. In the current research thin film biosensors of recombinant, Organophosphorus acid anhydrolase (OPAA) enzyme along with carbon quantum dots (CQDs) immobilized in thin films were developed. OPAA-CQDs thin film biosensors were used for the specific detection of two OPs Ethyl Paraoxon (EP) and Methyl Parathion (MP) in river water and household water supply. Recombinant OPAA enzyme was expressed in E. Coli, purified and immobilized on the CQD containing chitosan thin films. The CQDs used for this purpose were developed by a one-pot hydrothermal method from phthalic acid and Tri ethylene diamine. The properties of CQDs, OPAA and thin films were characterized using techniques like XPS, TEM, XRD, enzyme activity and CLSM measurements. Biosensing studies of EP and MP were performed by taking fluorescence measurements using a fiber optic spectrometer. The analytical parameters of biosensing were compared against an estimation carried out using the HPLC method. The biosensing performance indicates that the OPAA-CQDs thin film-based biosensors were able to detect both EP and MP in a range of 0–100 μM having a detection limit of 0.18 ppm/0.69 ppm for EP/MP, respectively with a response time of 5 min. The accuracy of estimation of EP/MP when spiked in water resources lie in the range of ∼100–102% which clearly indicates the OPAA-CQD based thin film biosensors can function as a point-of-use method for the detection of OP pesticides in complex water resources. © 2023 Elsevier Inc.
URI: https://doi.org/10.1016/j.envres.2023.117855
https://dspace.iiti.ac.in/handle/123456789/13054
ISSN: 0013-9351
Type of Material: Journal Article
Appears in Collections:Department of Biosciences and Biomedical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: