Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/14927
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGoyal, Vipinen_US
dc.contributor.authorVerma, Girish Chandraen_US
dc.date.accessioned2024-12-18T10:34:08Z-
dc.date.available2024-12-18T10:34:08Z-
dc.date.issued2024-
dc.identifier.citationGoyal, V., Verma, G., & Dixit, U. S. (2024). In-vitro study of Ti6Al4V alloy fabricated by laser-based additive manufacturing for orthopedic implant applications. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. Scopus. https://doi.org/10.1177/09544089241289723en_US
dc.identifier.issn0954-4089-
dc.identifier.otherEID(2-s2.0-85207134226)-
dc.identifier.urihttps://doi.org/10.1177/09544089241289723-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/14927-
dc.description.abstractThe Ti6Al4V alloy is widely used in orthopedic implants due to its excellent mechanical properties and biocompatibility. However, traditional manufacturing techniques are unable to fabricate complex geometrical shapes with tailored properties. This leads to premature failure due to wear, corrosion, and poor osseointegration. Recent advancements in laser-based additive manufacturing, particularly in direct metal laser sintering (DMLS), offer new opportunities to produce Ti6Al4V implants with tailored microstructures, mechanical properties, and biocompatibility. However, wear, corrosion, and cell viability behavior, required for evaluating the biomedical applicability of Ti6Al4V alloy produced through the DMLS route have not been reported. The present study fulfills this gap in the literature. Micro structural study revealed that DMLS-produced Ti6Al4V has a porous and fine grain structure (with mostly α′ phase) without any crack formation due to the controlled parameters during DMLS. Corrosion tests were conducted in simulated body fluid as an electrolytic media, while fibroblast cell lines were used to evaluate the cell viability. Compared to the conventional cast product, DMLS-produced Ti6Al4V alloy exhibited significantly higher porosity (4.8 times), scratch resistance (23.25%), wear resistance (11.53%), corrosion resistance (16.56%), and cell growth. (4.37%), thus making it a more suitable alloy for implants. © IMechE 2024.en_US
dc.language.isoenen_US
dc.publisherSAGE Publications Ltden_US
dc.sourceProceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineeringen_US
dc.subjectbiomedical engineeringen_US
dc.subjectcell viabilityen_US
dc.subjectcorrosionen_US
dc.subjectdirect metal laser sinteringen_US
dc.subjectTi6Al4V alloyen_US
dc.titleIn-vitro study of Ti6Al4V alloy fabricated by laser-based additive manufacturing for orthopedic implant applicationsen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Mechanical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: