Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/17050
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGoyal, Vipinen_US
dc.contributor.authorVerma, Girish Chandraen_US
dc.date.accessioned2025-10-31T17:40:59Z-
dc.date.available2025-10-31T17:40:59Z-
dc.date.issued2025-
dc.identifier.citationGoyal, V., Verma, G. C., & Katiyar, J. K. (2025). Physio-Tribocorrosion Performance of Additively Manufactured Ti6Al4V Alloy in Different Print Directions for Implant Application. Metals and Materials International. https://doi.org/10.1007/s12540-025-02063-xen_US
dc.identifier.issn1598-9623-
dc.identifier.issn2005-4149-
dc.identifier.otherEID(2-s2.0-105019218546)-
dc.identifier.urihttps://dx.doi.org/10.1007/s12540-025-02063-x-
dc.identifier.urihttps://dspace.iiti.ac.in:8080/jspui/handle/123456789/17050-
dc.description.abstractAdditively manufactured (AM) components exhibit orthotropic properties, which can lead to spatial variations in their mechanical properties and functional performance. As a result, implants fabricated using these techniques may also have direction-dependent properties. Therefore, it is very important to evaluate the orthotropic behavior of AM-produced Ti6Al4V (Ti64) alloy for improving the reliability and accurately predicting the service life of such implants. This study investigates the tribological and corrosion properties of scan direction (SD) and build direction (BD) samples manufactured using the direct metal laser sintering (DMLS) technique. Along with different print direction samples, cast-produced Ti64 samples were also tested as a reference. Both the corrosion and tribological characterizations were carried out in phosphate-buffered saline to mimic the human body condition. The tribological property was evaluated using a ball-on-disk tribometer at a sliding speed of 0.157 m/s and a sliding distance of 141.3 m against Al<inf>2</inf>O<inf>3</inf> balls. These tests were carried out at three different 5 N, 10 N, and 20 N loads to gauge the material wear properties in various loading conditions. Apart from this, other characterizations, like microstructural, elemental composition, XPS, wettability, etc., were also performed to understand the wear and corrosion results. The results show that the BD samples possess a lower wear rate (WR) and coefficient of friction (COF) than the SD samples. The microstructural study revealed that this is mainly due to the higher surface hardness and finer grain size. On the other hand, the corrosion rate (CR) was also evaluated using the open circuit potential (OCP) and potentiodynamic polarization (PDP) test. The result shows that DMLS-manufactured Ti64 alloy has lower CR, especially in BD, which is attributed to the formation of a strong passive layer of oxide on the surface. Based on the obtained result, it can be concluded that the DMLS-manufactured Ti64 samples from BD have the highest corrosion and wear resistance due to the higher surface hardness and the presence of a stable oxide layer. Therefore, it can be preferably used in orthopedic applications as compared to both SD and cast-Ti64 alloy. © 2025 Elsevier B.V., All rights reserved.en_US
dc.language.isoenen_US
dc.publisherKorean Institute of Metals and Materialsen_US
dc.sourceMetals and Materials Internationalen_US
dc.subjectAdditive manufacturingen_US
dc.subjectKnee implanten_US
dc.subjectPhosphate buffered salineen_US
dc.subjectTi6Al4Ven_US
dc.subjectTribologyen_US
dc.titlePhysio-Tribocorrosion Performance of Additively Manufactured Ti6Al4V Alloy in Different Print Directions for Implant Applicationen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Mechanical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: