Title: | Histogram error based algorithm for efficient collimation testing |
Authors: | Dhanotia, Jitendra Bhatia, Vimal |
Keywords: | CCD cameras;Graphic methods;Imaging techniques;Interferometry;Measurement;Optical communication;Accuracy and precision;Collimated beams;collimation;Collimation testing;Element by elements;Normalized histograms;Ronchi grating;Self imaging;Errors |
Issue Date: | 2019 |
Publisher: | IOP Publishing Ltd |
Citation: | Dhanotia, J., Bande, S., Bhatia, V., & Prakash, S. (2019). Histogram error based algorithm for efficient collimation testing. Journal of Optics (United Kingdom), 21(9) doi:10.1088/2040-8986/ab3870 |
Abstract: | This communication reports an investigation undertaken towards setting collimation of an optical beam using a self-imaging technique and histogram error (HE) based approach. The beam under test illuminates an amplitude type Ronchi grating. After the grating, a beam splitter is placed such that the grating's self-images are formed in two perpendicular directions, at the different Talbot planes. The images are then recorded using two identical CCD cameras. Towards implementing a HE based algorithm, first, element-by-element subtraction of the normalized histogram of both self-images is computed. Next, the sum of the elements of the resultant image matrix is determined. Finally, the square of the sum yields the HE. HE provides an estimate of the collimation errors in the beam. For an incident collimated beam, the self-images recorded at different Talbot planes have identical unit magnification with respect to the grating; however, when the beam diverges or converges, the size and fringe width of self-images are differentially magnified or demagnified. Hence, when the beam is collimated, the HE is minimum. For the decollimated beam, the value of HE is higher, and increases as the decollimation errors increase. Using the proposed method, we could set the collimation position to a resolution of 1 μm, which relates to ±0.22 μ radians in terms of collimation angle (for a lens of focal length 300 mm and diameter 40 mm). Experimental results conclusively establish the viability of the technique. Good accuracy and precision in the measurement have been achieved. © 2019 IOP Publishing Ltd. |
URI: | https://doi.org/10.1088/2040-8986/ab3870 https://dspace.iiti.ac.in/handle/123456789/5715 |
ISSN: | 2040-8978 |
Type of Material: | Journal Article |
Appears in Collections: | Department of Electrical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: