Title: Design, fabrication and testing of a 3D printed FBG pressure sensor
Authors: Borana, Lalit
Keywords: 3D printers;Cyclic loads;Electric sensing devices;Embeddings;Fabrication;Infill drilling;Polyesters;Pressure sensors;Printing presses;Product design;3-D printing;Calibration tests;Cyclic loading test;Encapsulation methods;Measurement sensitivity;Poly lactic acid;Sensing performance;Vertical pressure;Fiber Bragg gratings
Issue Date: 2019
Publisher: Institute of Electrical and Electronics Engineers Inc.
Citation: Hong, C., Zhang, Y., & Borana, L. (2019). Design, fabrication and testing of a 3D printed FBG pressure sensor. IEEE Access, 7, 38577-38583. doi:10.1109/ACCESS.2019.2905349
Abstract: In this paper, a fiber Bragg grating (FBG) pressure sensor was designed and fabricated using 3D printing method for the measurement of vertical pressure. The raw material used for the fabrication of this new pressure sensor was Polylactic Acid (PLA). The effectiveness of embedding FBG sensors inside printed PLA material was first examined taking into account different infill densities. It is found that the FBG sensor can be successfully embedded into PLA material without sacrificing its sensing performance. The change of infill density has no influence on both peak and residual wavelength change of FBG sensors during and after the printing process. All FBG sensors printed inside PLA prototype with different infill density values exhibit almost the same peak and residual wavelength rise values in the printing process. In addition, the higher the density value, the longer the time required to finish printing process. A simple FBG pressure sensor was designed and fabricated according to the successful experience of embedding FBG sensors into printed PLA. Measurement performance of this FBG pressure sensor was examined in laboratory cyclic loading tests. Calibration tests indicate that the maximum measured vertical pressure of this new pressure sensor was 2000 kPa with a measurement sensitivity of 13.22 kPa/pm. © 2019 IEEE.
URI: https://doi.org/10.1109/ACCESS.2019.2905349
https://dspace.iiti.ac.in/handle/123456789/6350
ISSN: 2169-3536
Type of Material: Journal Article
Appears in Collections:Department of Civil Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: