Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/7131
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKulkarni, Aniket P.en_US
dc.contributor.authorDeshmukh, Devendraen_US
dc.date.accessioned2022-03-17T01:00:00Z-
dc.date.accessioned2022-03-21T10:52:37Z-
dc.date.available2022-03-17T01:00:00Z-
dc.date.available2022-03-21T10:52:37Z-
dc.date.issued2019-
dc.identifier.citationKulkarni, A. P., & Deshmukh, D. (2019). Improvements in laser sheet dropsizing using numerical and experimental techniques. International Journal of Multiphase Flow, 110, 273-281. doi:10.1016/j.ijmultiphaseflow.2018.09.004en_US
dc.identifier.issn0301-9322-
dc.identifier.otherEID(2-s2.0-85054469121)-
dc.identifier.urihttps://doi.org/10.1016/j.ijmultiphaseflow.2018.09.004-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/7131-
dc.description.abstractLaser sheet drop sizing (LSD) technique is used along with numerical tools to improve the accuracy of planar drop sizing in dense sprays. The multiple scattering in Mie and Planar Laser Induced Fluorescence (PLIF) signal is reduced using the Structured Laser Illumination Planar Imaging (SLIPI). The numerical corrections are applied to reduce error due to laser sheet scattering, absorption and auto-absorption of the PLIF signal. A novel methodology is proposed to measure the planar distribution of optical depth (OD) in airblast sprays using the LSD technique. The optical depth is observed to increase with an increase in Gas to Liquid mass Ratio (GLR) in air-blast sprays. It is demonstrated that, dependency of the LSD technique on another independent drop sizing technique can be minimized in airblast sprays using an empirical correlation. It is observed that the use of SLIPI improves the reliability of the LSD technique even in optically dilute sprays. The improvement in LSD techniques is significantly higher in dense sprays with the optical depth higher than 2.5. The maximum Mean Average Percentage Error (MAPE) reduced from 40% in conventional LSD technique to ∼12% for SLIPI-LSD with numerical corrections in dense sprays with OD ∼ 6. For the sprays with higher droplet density, it is necessary to use SLIPI in a combination with numerical correction techniques to improve the accuracy of the planar droplet sizing technique. © 2018 Elsevier Ltden_US
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.sourceInternational Journal of Multiphase Flowen_US
dc.subjectOptical propertiesen_US
dc.subjectSurface mount technologyen_US
dc.subjectCorrection techniquesen_US
dc.subjectEmpirical correlationsen_US
dc.subjectExperimental techniquesen_US
dc.subjectNovel methodologyen_US
dc.subjectNumerical correctionsen_US
dc.subjectOptical depthen_US
dc.subjectPlanar laser-induced fluorescence signalsen_US
dc.subjectSLIPIen_US
dc.subjectDropsen_US
dc.titleImprovements in laser sheet dropsizing using numerical and experimental techniquesen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Mechanical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: