Please use this identifier to cite or link to this item: https://dspace.iiti.ac.in/handle/123456789/7138
Full metadata record
DC FieldValueLanguage
dc.contributor.authorParey, Ananden_US
dc.date.accessioned2022-03-17T01:00:00Z-
dc.date.accessioned2022-03-21T10:52:39Z-
dc.date.available2022-03-17T01:00:00Z-
dc.date.available2022-03-21T10:52:39Z-
dc.date.issued2018-
dc.identifier.citationRaghuwanshi, N. K., & Parey, A. (2018). Experimental measurement of mesh stiffness by laser displacement sensor technique. Measurement: Journal of the International Measurement Confederation, 128, 63-70. doi:10.1016/j.measurement.2018.06.035en_US
dc.identifier.issn0263-2241-
dc.identifier.otherEID(2-s2.0-85048873838)-
dc.identifier.urihttps://doi.org/10.1016/j.measurement.2018.06.035-
dc.identifier.urihttps://dspace.iiti.ac.in/handle/123456789/7138-
dc.description.abstractAccurate measurement of mesh stiffness of a given gear pair is important for understanding the dynamics of gearboxes. Photoelasticity and strain gauge techniques are the only experimental techniques that are suggested to measure the mesh stiffness of cracked spur gear pairs in the literature. In the above two experimental techniques, the gear body deformation was not taken into account for the mesh stiffness measurement. In this work, a new experimental technique is designed to measure the mesh stiffness. For this, a well-established laser displacement sensor technique (LDST) is used. In this method spur gear tooth deflection is measured along the line of action by using the laser displacement sensor, consequently, gear mesh stiffness is calculated. The experiment is also performed on cracked tooth pair to measure the mesh stiffness. The main advantage of this experimental technique is to measure the total deflection of gear tooth with gear body deformation. The investigation shows that the gear mesh stiffness is reduced when crack size is increased. For validating the results of the experiment, FEA (finite element analysis) is performed to estimate the mesh stiffness. The mean mesh stiffness is measured as 0.76 × 104 N/mm by LDST and 0.96 × 104 N/mm by FEA for the healthy case. The results of the experiment are found having a good match with that obtained from FE method. © 2018 Elsevier Ltden_US
dc.language.isoenen_US
dc.publisherElsevier B.V.en_US
dc.sourceMeasurement: Journal of the International Measurement Confederationen_US
dc.subjectDeformationen_US
dc.subjectGear teethen_US
dc.subjectMesh generationen_US
dc.subjectSpur gearsen_US
dc.subjectStrain gagesen_US
dc.subjectAccurate measurementen_US
dc.subjectCracked toothen_US
dc.subjectExperimental techniquesen_US
dc.subjectGear mesh stiffnessen_US
dc.subjectLaser displacement sensorsen_US
dc.subjectMesh stiffnessen_US
dc.subjectSpur gear pairsen_US
dc.subjectStrain gauge techniqueen_US
dc.subjectStiffnessen_US
dc.titleExperimental measurement of mesh stiffness by laser displacement sensor techniqueen_US
dc.typeJournal Articleen_US
Appears in Collections:Department of Mechanical Engineering

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetric Badge: