Please use this identifier to cite or link to this item:
https://dspace.iiti.ac.in/handle/123456789/7299
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sahu, Santosh Kumar | en_US |
dc.date.accessioned | 2022-03-17T01:00:00Z | - |
dc.date.accessioned | 2022-03-21T10:53:30Z | - |
dc.date.available | 2022-03-17T01:00:00Z | - |
dc.date.available | 2022-03-21T10:53:30Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Chougule, S. S., & Sahu, S. K. (2015). Performance of carbon nanotubes-water nanofluid charged wickless heat pipe flat plate solar collectors having different filling ratio. Journal of Solar Energy Engineering, Transactions of the ASME, 137(2) doi:10.1115/1.4028701 | en_US |
dc.identifier.issn | 0199-6231 | - |
dc.identifier.other | EID(2-s2.0-84993969486) | - |
dc.identifier.uri | https://doi.org/10.1115/1.4028701 | - |
dc.identifier.uri | https://dspace.iiti.ac.in/handle/123456789/7299 | - |
dc.description.abstract | An experimental study was carried out to investigate the thermal performance of solar heat pipe collector at outdoor test condition. The thermal performance of wickless heat pipe solar collector was investigated by using CNT-water nanofluid. Carbon nano-tubes (CNT) nanoparticles with diameter 10-12nm and 0.1-10 μm length were used in the present experimental investigation. The effects of various filling ratio (F.R.) (50%, 60%, and 70%) and coolant flow rate on thermal performance were discussed in this study. © Copyright 2015 by ASME. | en_US |
dc.language.iso | en | en_US |
dc.publisher | American Society of Mechanical Engineers (ASME) | en_US |
dc.source | Journal of Solar Energy Engineering, Transactions of the ASME | en_US |
dc.subject | Carbon nanotubes | en_US |
dc.subject | Filling | en_US |
dc.subject | Heat pipes | en_US |
dc.subject | Heat transfer | en_US |
dc.subject | Solar collectors | en_US |
dc.subject | Yarn | en_US |
dc.subject | Experimental investigations | en_US |
dc.subject | Filling ratio | en_US |
dc.subject | Flat-plate collector | en_US |
dc.subject | Flat-plate solar collectors | en_US |
dc.subject | Heat-pipe solar collectors | en_US |
dc.subject | Nanofluids | en_US |
dc.subject | Solar heat pipe collectors | en_US |
dc.subject | Thermal Performance | en_US |
dc.subject | Nanofluidics | en_US |
dc.title | Performance of carbon nanotubes-water nanofluid charged wickless heat pipe flat plate solar collectors having different filling ratio | en_US |
dc.type | Journal Article | en_US |
Appears in Collections: | Department of Mechanical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: