Please use this identifier to cite or link to this item:
https://dspace.iiti.ac.in/handle/123456789/7310
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sharma, V.K. | en_US |
dc.contributor.author | Emadabathuni, Anil Kumar | en_US |
dc.date.accessioned | 2022-03-17T01:00:00Z | - |
dc.date.accessioned | 2022-03-21T10:53:34Z | - |
dc.date.available | 2022-03-17T01:00:00Z | - |
dc.date.available | 2022-03-21T10:53:34Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Sharma, V. K., Anil Kumar, E., & Srinivasa Murthy, S. (2015). Influence of dynamic operating conditions on the performance of metal hydride based solid sorption cooling systems. International Journal of Hydrogen Energy, 40(2), 1108-1115. doi:10.1016/j.ijhydene.2014.11.084 | en_US |
dc.identifier.issn | 0360-3199 | - |
dc.identifier.other | EID(2-s2.0-84916910356) | - |
dc.identifier.uri | https://doi.org/10.1016/j.ijhydene.2014.11.084 | - |
dc.identifier.uri | https://dspace.iiti.ac.in/handle/123456789/7310 | - |
dc.description.abstract | The performance of metal hydride based solid sorption cooling systems depends on the driving pressure differential, and the rate of hydrogen transfer between coupled metal hydride beds during cooling and regeneration processes. Conventionally, the mid-plateau pressure difference obtained from 'static' equilibrium PCT data are used for the thermodynamic analysis. It is well known that the processes are 'dynamic' because the pressure and temperature, and hence the concentration of the hydride beds, are continuously changing. Keeping this in mind, the pair of La0.9Ce0.1Ni5 - LaNi4.7Al0.3 metal hydrides suitable for solid sorption cooling systems were characterised using both static and dynamic methods. It was found that the PCT characteristics, and the resulting enthalpy (ΔH) and entropy (ΔS) values, were significantly different for static and dynamic modes of measurements. In the present study, the solid sorption metal hydride cooling system is analysed taking in to account the actual variation in the pressure difference (ΔP) and the dynamic enthalpy values. Compared to 'static' property based analysis, significant decrease in the driving potentials and transferrable amounts of hydrogen, leading to decrease in cooling capacity by 57.8% and coefficient of performance by 31.9% are observed when dynamic PCT data at the flow rate of 80 ml/min are considered. © 2014 Hydrogen Energy Publications, LLC. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ltd | en_US |
dc.source | International Journal of Hydrogen Energy | en_US |
dc.subject | Cerium | en_US |
dc.subject | Cooling | en_US |
dc.subject | Enthalpy | en_US |
dc.subject | Hydrides | en_US |
dc.subject | Hydrogen | en_US |
dc.subject | Metals | en_US |
dc.subject | Sorption | en_US |
dc.subject | Thermoanalysis | en_US |
dc.subject | Thermoelectric equipment | en_US |
dc.subject | Metal hydrides | en_US |
dc.subject | Plateau slope | en_US |
dc.subject | Solid sorption | en_US |
dc.subject | Thermodynamic cycle | en_US |
dc.subject | Thermodynamic data | en_US |
dc.subject | Cooling systems | en_US |
dc.title | Influence of dynamic operating conditions on the performance of metal hydride based solid sorption cooling systems | en_US |
dc.type | Journal Article | en_US |
Appears in Collections: | Department of Mechanical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: