Title: | Three-Phase Single-Stage Photovoltaic System with Synchronverter Control: Power System Simulation Studies |
Authors: | Sonawane, Ajinkya J. Umarikar, Amod C. |
Keywords: | Circuit simulation|Controllers|Electric fault currents|Electric inverters|Electric power system control|Electric power transmission networks|Integrated circuits|Load testing|Power control|Solar cells|Synchronous generators|Timing circuits|Benchmark testing|Distribution generators|Grid-connected|Grid-connected inverte|Integrated circuit modeling|Load modeling|Photovoltaic-synchronverte system|Photovoltaics|Power-control|Resistance|Synchronverte|Virtual synchronoi generator|Voltage control |
Issue Date: | 2022 |
Publisher: | Institute of Electrical and Electronics Engineers Inc. |
Citation: | Sonawane, A. J., & Umarikar, A. C. (2022). Three-phase single-stage photovoltaic system with synchronverter control: Power system simulation studies. IEEE Access, 10, 23408-23424. doi:10.1109/ACCESS.2022.3153505 |
Abstract: | The performance of a grid forming inverter integrating solar PV/Wind farms with the grid is currently a topic of wide interest. Synchronverter control is one of the well-known grid forming converter techniques. Evaluation of synchronverter control in the benchmark system will help in understanding its operation when connected to a larger system. Therefore, this article investigates the performance of three phase single-stage photovoltaic (PV) system with a synchronverter control in the North American medium voltage (MV) benchmark system. The main objective is to conduct an exploratory study of the PV based synchronverter system when subjected to various disturbances. The modeling of PV array, controllers like synchronverter, dc-link voltage control, ac voltage control and their design is discussed in detail. The simulation studies for different cases are carried out by creating various disturbances like changes in solar radiation, temperature, load, faults, etc., in the benchmark system. Furthermore, under fault conditions, response with/without voltage droop mechanism in synchronverter is studied. All the offline simulations are carried out in PSCAD/EMTDC environment. Further, the real time test studies are validated on Controller-Hardware-In-Loop (CHIL) platform in Real-Time-Digital-Simulator (RTDS). From this simulation study, it is concluded that Synchronverter Control can be a viable option when used as a grid forming technique. © 2013 IEEE. |
URI: | https://dspace.iiti.ac.in/handle/123456789/9959 https://doi.org/10.1109/ACCESS.2022.3153505 |
ISSN: | 2169-3536 |
Type of Material: | Journal Article |
Appears in Collections: | Department of Electrical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: