Please use this identifier to cite or link to this item:
https://dspace.iiti.ac.in/handle/123456789/10846
Title: | Experimental investigation of flow and thermal characteristics of synthetic jet issuing from sharp-edged orifices |
Authors: | Sharma, PawanSahu, Santosh Kumar;Yadav, Harekrishna; |
Keywords: | Anemometers; Heat transfer; Jets; Reynolds number; Thermography (imaging); Diverging-shaped orifice; Flow characteristic; Flow recirculation; Heat transfer rate; Hot wire anemometers; IR-thermography; Opening angle; Sharp-edged orifice; Synthetic jet; Synthetic jets; Orifices |
Issue Date: | 2022 |
Publisher: | Taylor and Francis Ltd. |
Citation: | Sharma, P., Sahu, S. K., & Yadav, H. (2022). Experimental investigation of flow and thermal characteristics of synthetic jet issuing from sharp-edged orifices. Experimental Heat Transfer, doi:10.1080/08916152.2022.2105449 |
Abstract: | The present experimental study reports the flow and heat transfer characteristics of a synthetic jet issuing from a sharp-edged orifice (diverging-shaped orifice). The experiments are carried out for a varied range of opening angles of sharp-edged orifices (θ = 0°, 30°, 60°, 90°, and 120°), Reynolds number (Re = 3243–8143), different jet-to-surface spacings (z/d = 1–16), and for two different values of orifice thicknesses, t = 5 mm (t/d = 0.33) and 10 mm (t/d = 0.66). The hot-wire anemometry is used to study the flow characteristics of synthetic jet, while heat transfer characteristics are studied by using a thermal imaging technique. The time-averaged flow fields associated with sharp-edged orifices reveal that orifices with t = 5 mm and 10 mm exhibit saddle-backed and top-hat velocity profile shapes, respectively. The results show that for a square-edge orifice (θ = 0°), the heat transfer rate decreases with an increase in orifice plate thickness from 5 to 10 mm, while the opposite trend in heat transfer is observed with sharp-edged orifice. The heat transfer rate with a 10 mm thick sharp-edged orifice is higher than the 5 mm thick sharp-edged orifice for all the tested opening angles. Furthermore, the results also show that for sharp-edged orifices, the heat transfer rate increases with the increase in opening angle from θ = 0° to 60°, while it decreases with further increasing from θ = 60° to 120°. The maximum value of average Nusselt number (Nuavg) is obtained for θ = 60° for both the orifice thicknesses (t = 5 and 10 mm), and this effect is found to be more pronounced for t = 10 mm orifice. For sharp-edged orifice (θ = 60°), the maximum enhancement in Nuavg is found to be 12.66% and 23% higher for t = 5 mm and 10 mm, respectively, compared to the equivalent square-edged orifice (θ = 0°). The cause for variation in heat transfer rate with sharp-edged orifices is interpreted due to the effect of flow recirculation and mass flow rate. A correlation has been proposed for Nuavg as a function of different opening angles. The present finding is useful for the optimization of the synthetic jet geometrical parameters for the effective heat transfer rate. © 2022 Taylor & Francis. |
URI: | https://doi.org/10.1080/08916152.2022.2105449 https://dspace.iiti.ac.in/handle/123456789/10846 |
ISSN: | 0891-6152 |
Type of Material: | Journal Article |
Appears in Collections: | Department of Mechanical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: