Please use this identifier to cite or link to this item:
https://dspace.iiti.ac.in/handle/123456789/7314
Title: | Analysis of multi-region conduction-controlled rewetting of a hot surface with precursory cooling by variational integral method |
Authors: | Sahu, Santosh Kumar |
Keywords: | Cooling;Heat transfer coefficients;Peclet number;Analytical results;Axial direction;Closed-form expression;Continuous films;Incipient boiling;Re-wetting;Three-region;Variational integral;Sputtering |
Issue Date: | 2014 |
Publisher: | Elsevier Ltd |
Citation: | Agrawal, M. K., & Sahu, S. K. (2014). Analysis of multi-region conduction-controlled rewetting of a hot surface with precursory cooling by variational integral method. Applied Thermal Engineering, 73(1), 267-276. doi:10.1016/j.applthermaleng.2014.07.062 |
Abstract: | An analytical model has been proposed to evaluate rewetting velocity by employing variational integral method. The model considers three distinct regions: a dry region ahead of wet front, the sputtering region immediately behind the wet front and a continuous film region further upstream. Two different models are considered in the sputtering region for the analysis. First model considers a constant heat transfer coefficient in the sputtering region; while the other one propose a variation in heat transfer coefficient in the sputtering region. Both the models consider a constant heat transfer coefficient in the wet region and exponentially varying heat transfer coefficient in the dry region ahead of wet front. For all the cases the closed form expression is obtained for temperature field along axial direction. Relationship between various rewetting parameters such as; Peclet number, Biot number, dry wall temperature, incipient boiling temperature, sputtering length, magnitude of precursory cooling and the extent of precursory cooling has been obtained from the analysis. Present prediction obtained by employing variational integral method exhibits an excellent agreement with the previous analytical results [1-4] and test data [5,6,23]. © 2014 Elsevier Ltd. All rights reserved. |
URI: | https://doi.org/10.1016/j.applthermaleng.2014.07.062 https://dspace.iiti.ac.in/handle/123456789/7314 |
ISSN: | 1359-4311 |
Type of Material: | Journal Article |
Appears in Collections: | Department of Mechanical Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Altmetric Badge: